Environmental Conditioning Unit
Model 2590 for NVH Dynamometers

System Features |
|



System Features |
|
The Model 2590 Environmental Conditioning Unit (ECU) is utilized to provide specified controlled temperature and humidity conditions. This system is designed to allow investigative studies for brake NVH under extreme environmental conditions within a large walk-in sized test enclosure. Parameters are programmed through the integrated ProLink™ dynamometer control system.
The ECU is built as an integrated system with a typical floor or mezzanine installation. A direct expansion refrigeration system is utilized and either water-cooled or air-cooled condensers are available. Insulated ducts and silencers are utilized. Airborne dust particles are collected via a filtration system.
The advantages of this system include dual coil for low temperature/high humidity operation. Rapid cool down with direct brake and enclosure conditioning. Available options include system shut-off during noise measurement collection.

Typical Specifications |
|
| Temperature Range | -20 to 40°C (-4 to 104°F) |
| Temperature Control | ± 2°C (3.6°F) 5 to 40°C (>41 to 104°F) ± 5°C (9°F) -20 to 5°C (>-4 to 41°F) |
| Humidity Range | 20% to 90% RH, 5 to 40°C, limited by 1°C Dew Point |
| Humidity Control | ± 5% RH |
| Airflow Rate | 4250 m³/hr through 254mm duct (2500 cfm through 10” duct) |
| Portable Water | 2 lpm (0.5 gpm) |
| Drain | Sanitary drain required |
| Air Requirement | 1 drop @ 0.15m³/hr @ 720 Pa (5 cfm @ 15 psi) |
| Cooling Method | Water Cooled (standard) 151 lpm @ 30º C (40 gpm @ 80º F) |
Options |
|